Testing Parameters
Random vibration test one: active monitoring of one channel and post optical measurements of all 12 channels. (14.1 grms, 1 minute/axis)
Thermal test:
- 30 cycles, -20 °C to +85 °C, 1 °C/min.
- 42 cycles, -20 °C to +85 °C, 3 °C/min up, 2 °C/min down.
Random vibration test two: active monitoring of one channel and post optical measurements of all 12 channels. (20 grms, 3 minutes/axis)